testo 440 | Lux Kit

Previous 2 / 3 Next

Quantity
Add Quotation


Download Files

testo-440-brochure-EN-SMI-2018.pdf (2.12 MB)
testo 440 | Lux Kit
 
  • Intuitive: clearly structured measurement menu for long-term measurement and determination of illuminance according to the V-lambda curve , thus for all common light sources
  • Precise: standard-compliant accuracy according to DIN EN 13032-1 and class C according to DIN 5032-7
  • Convenient: non-slip probe contact surface for convenient positioning at the measuring location, internal data storage and USB port for data export
  • As multifaceted as your challenges themselves: the air velocity and IAQ measuring instrument can be expanded with a large portfolio of digital probes
Kit for measuring the illuminance in workplaces, for example in offices or in production areas. Keep the testo 440 air velocity and IAQ measuring instrument and a lux probe safely stowed away in the case. So you can get down to work straight away!
 
 
Product Description
 
Opt for the kit that includes the testo 440 air velocity and IAQ measuring instrument and lux probe for measuring the illuminance in workplaces.
 
 
testo 440 Lux Kit in detail
 
testo 440 air velocity and IAQ measuring instrument:
  • No task is too challenging, no application too specialized: the testo 440 combines a compact hand-held measuring instrument with intuitive measurement menus and a wide selection of air velocity and IAQ probes
  • Clearly structured measurement menu for long-term measurement: for long-term monitoring, enter the measurement time and measuring cycle in the measuring instrument and record measurement data trends
  • Easy storage and evaluation of measurement data. Measurement data memory for up to 7500 measurement protocols, which can be read via a USB port and further processed as a CSV file on the computer (e.g. with Excel)
  • Practical magnets for easy attachment of the measuring instrument to metal surfaces
  • Automatic detection of probes, e.g. lux probe
  • Large, backlit colour display
 
Lux probe:
  • Use the lux probe to check the illuminance in offices and production areas, hospitals, museums or schools
  • Measuring range: 0 to +100000 lux
  • Standard-compliant: accuracy according to DIN EN 13032-1 and class C according to DIN 5032-7
  • Suitable for all common lamps and light sources: assessment according to the V-lambda curve
  • White or warm light LEDs (K< 5000) can be measured without any problem
  • Use the fixed cable to connect the lux probe to the testo 440 air velocity and IAQ measuring instrument. Thanks to the 1.4 m cable, you can position the probe in such a way that the measurement is not affected by your shadow
  • Intelligent calibration concept: the air velocity and IAQ measuring instrument remains in continuous use, since only the lux probe needs to be sent in for calibration
 
Delivery Scope
  • testo 440 air velocity and IAQ measuring instrument, 3 x AA batteries, USB cable and calibration protocol (0560 4401)
  • Lux probe with fixed cable (cable length 1.4 m) and calibration protocol (0635 0551)
  • Basic case for testo 440 and 1 probe
 
Techincal Data
 

Temperature - NTC
Measuring range -40 to +150 °C
Accuracy ±0.4 °C (-40 to -25.1 °C)
±0.2 °C (-+25 to +74.9 °C)
±0.4 °C (+75 to +99.9 °C)
±0.5 % of mv (Remaining Range)
Resolution 0.1 °C
 
Temperature - TC Type K (NiCr-Ni)
Measuring range -200 to +1370 °C
Accuracy ±(0.3 °C + 0.1 % of mv)
Resolution 0.1 °C
 
General technical data
Dimensions 154 x 65 x 32 mm
Operating temperature -20 to +50 °C
Connectable probes 1 x digital probe with cable or 1 x Temperature NTC TUC, 1 x digital Bluetooth probe or testo Smart Probe, 1 x Temperature TC Type K
Battery type 3 AA mignon 1.5 V
Battery life 12 h (typically vane measurement)
Data transfer Bluetooth®; USB interface
Storage temperature -20 to +50 °C
Weight 250 g

 
Applications
 
Long-term monitoring of indoor air quality
 
Poor indoor air quality due to excessive concentrations of CO2 can cause tiredness, lack of concentration and even illness. With its menu for recording readings, the testo 440 air velocity and IAQ measuring instrument is ideal for monitoring the indoor air quality. Enter the measurement time and the measuring cycle – and, for example, track the change in CO2 concentration or humidity and temperature values over the course of the day. Simply choose between probes with Bluetooth® or fixed cable for CO2, CO or humidity (please order probes separately).
 
Turbulence measurement in accordance with EN ISO 7730 / ASHRAE 55
 
Determine the degree of turbulence and the draught risk in the workplace: draught restricts the comfort level and is the most common cause of complaints about the indoor climate. The turbulence probe (please order separately) measures air velocity and air temperature, and automatically calculates the draught risk and the degree of turbulence in accordance with EN ISO 7730/ASHRAE 55.

For convenient measurements at varying heights, we recommend using our measuring tripod for comfort level measurement (please order separately). This makes it very easy to position turbulence probes in compliance with the standards.
 
Convenience and maximum flexibility for duct and outlet measurements
 
With our large range of air velocity probes (please order separately), you can carry out simple and convenient measurements even at locations that are difficult to access in ventilation ducts or at air outlets:
you will even find it easy to carry out measurements in particularly large ducts. This is because the extendable telescope on the hot wire and vane probe (Ø 16 mm) with universal handle can be further extended using the telescope extension – enabling you to attain a total length of 2 metres.

Carry out measurements at air/ceiling outlets effortlessly and without using a ladder. Fit your vane probe (Ø 100 mm) with the telescope with 90° angle and, if necessary, with the telescope extension (both can be ordered separately).

Greater freedom thanks to Bluetooth: the air velocity probes with Bluetooth have no inconvenient cable connection to the measuring instrument, and they transmit readings up to a distance of 20 m. Press the button on the probe to operate the measuring instrument – for example, to start and stop a series of measurements (timed mean calculation).

Attach the testo 440 air velocity and IAQ measuring instrument to metal surfaces (e.g. ducts) easily using the practical magnets.

Benefit from fast calculation of the volume flow: in the “volume flow” measurement menu of the multifunction measuring instrument, configure the dimensions and geometry of the duct cross-section – the measuring instrument shows you the volume flow straight away.
 
Range of probes for cleanrooms and laboratories
 
The testo 440 air velocity and IAQ measuring instrument is also ideal for a wide variety of applications in cleanrooms and laboratories in conjunction with the following probes (please order separately):
  • High-precision air velocity measurement on fume cupboards with the fume cupboard probe
  • Thanks to the low start-up speed of 0.1 m/s, the high-precision vane probe (Ø 100 mm) is ideal for laminar flow measurements in cleanrooms. It is available as a variant with Bluetooth or with fixed cable
  • To measure the humidity in cleanrooms, we recommend the high-precision humidity/temperature probe (0636 9771 or 0636 9772). With an accuracy of: ±(0.6% RH + 0.7 % of m.v.) (0 to 90% RH), it also meets the requirements for humidity measurements in this particularly sensitive area

Video Demo



 
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*  
   

You have 0 items in you cart. Would you like to checkout now?
0 items
available in