V Office 2, VO2-03-12,
Lingkaran SV,
Sunway Velocity,
Jalan Peel,
55100 Kuala Lumpur,
Malaysia.
+603-2742 7468
Terminal voltage | Measuring range | Resolution | Accuracy | Load current | Short circuit current |
125V (0 ... 10 %) | 0,125 ... 4 MΩ | 0.001 MΩ | ± (2% + 10 digits) | 1-mA @ Last 125 kΩ | <= 1-mA |
4,001 ... 40 MΩ | 0.01 MΩ | ± (2% + 10 digits) | |||
40,01 ... 400 MΩ | 0.1 MΩ | ± (4% + 5 digits) | |||
400,1 ... 1000 MΩ | 1 MΩ | ± (5% + 5 digits) | |||
250V (0 ... 10 %) | 0,125 ... 4 MΩ | 0.001 MΩ | ± (2% + 10 digits) | 1-mA @ Last 250 kΩ | <= 1-mA |
4,001 ... 40 MΩ | 0.01 MΩ | ± (2% + 10 digits) | |||
40,01 ... 400 MΩ | 0.1 MΩ | ± (3% + 2 digits) | |||
400,1 ... 1000 MΩ | 1 MΩ | ± (3% + 2 digits) | |||
500V (0 ... 10 %) | 0,125 ... 4 MΩ | 0.001 MΩ | ± (2% + 10 digits) | 1-mA @ Last 500 kΩ | <= 1-mA |
4,001 ... 40 MΩ | 0.01 MΩ | ± (2% + 10 digits) | |||
40,01 ... 400 MΩ | 0.1 MΩ | ± (3% + 2 digits) | |||
400,1 ... 1000 MΩ | 1 MΩ | ± (4% + 5 digits) | |||
1000 V (0 ... 10 %) | 0,125 ... 4 MΩ | 0.001 MΩ | ± (3% + 10 digits) | 1-mA @ Last 1 MΩ | <= 1-mA |
4,001 ... 40 MΩ | 0.01 MΩ | ± (2% + 10 digits) | |||
40,01 ... 400 MΩ | 0.1 MΩ | ± (3% + 2 digits) | |||
400,1 ... 1000 MΩ | 1 MΩ | ± (4% + 5 digits) |
Measuring range | Resolution | Accuracy | Max. open circuit voltage | Overload protection |
2,000 Ω | 0.001 Ω | ± (1.5% + 30 digits) | 5.8V | 250 Vrms |
20,00 Ω | 0.01 Ω | ± (1.5% + 3 digits) | 5.8V | 250 Vrms |
200,0 Ω | 0.1 Ω | ± (1.5% + 3 digits) | 5.8V | 250 Vrms |
2000 Ω | 1 Ω | ± (1.5% + 5 digits) | 5.8V | 250 Vrms |
Measuring range | Resolution | Max. open circuit voltage | Overload protection | Short circuit current |
2000 Ω | 0.01 Ω | 5.8V | 250 Vrms | >= 200-mA |
L-PE (Hi-Amp): Load current 4.0 A | ||
Measuring range | Resolution | Accuracy |
0.23 ... 9.99 Ω | 0.01 Ω | ± (4% + 4 digits) |
10.0 ... 99.9 Ω | 0.1 Ω | ± (4% + 4 digits) |
100 ... 999 Ω | 1 Ω | ± (4% + 4 digits) |
L-PE (without tripping): Load current 15-mA | ||
Measuring range | Resolution | Accuracy |
0.23 ... 9.99 Ω | 0.01 Ω | ± (5% + 6 digits) |
10.0 ... 99.9 Ω | 0.1 Ω | ± (5% + 6 digits) |
100 ... 999 Ω | 1 Ω | ± (5% + 6 digits) |
L-N: Load current 4.0 A | ||
Measuring range | Resolution | Accuracy |
0.23 ... 9.99 Ω | 0.01 Ω | ± (4% + 4 digits) |
10.0 ... 99.9 Ω | 0.1 Ω | ± (4% + 4 digits) |
100 ... 999 Ω | 1 Ω | ± (4% + 4 digits) |
RCD (In) | 10-mA, 30-mA, 100-mA, 300-mA, 650-mA, 1 A |
Factors | x 1/2, x1, x2, x5 |
Accuracy of the tripping time | ± (1% + 1 ms) |
Signal form of the test current | Sine (AC), pulse (DC) |
Tripping characteristics | G and S |
Release time | 0° or 180° |
Voltage range | 194 ... 260V AC (50/60 Hz) |
Accuracy of current measurement | ± (5% + 2 digits) |
RCD Types | Type A, Type B |
Measuring range | Resolution | Accuracy |
80...500 V AC/DC | 1 V | ± (2 % + 2 digits) |
Measuring range | Resolution | Accuracy |
45...65 Hz | 1 Hz | ±2 Hz |
Measuring range | Resolution | Accuracy |
0.00...99.99 Ω | 0.01 Ω | ± (2% + 30 digits) |
100.0...999.9 Ω | 0.1 Ω | ± (2% + 6 digits) |
1000...2000 Ω | 1 Ω | ± (2% + 6 digits) |
Power supply | 8 x 1.2 ... 1.5V AA batteries |
Operating time | ca. 15 h |
Measurement category | CAT III 600V |
Protection class | IP 65 |
Display | 3.5'' TFT (320 x 240 Pixel) |
Operating environment |
0 ... 45°C 0 ... 95% rH, non condensing |
Measurements | 24.2 x 10.5 x 14.5 cm |
Weight | 1.56 kg / 3.4 lbs |
PE test (protective conductor) | available, error |
PP simulation (charging cable coding) | open, 13 A, 20 A, 32 A, 63 A |
CP simulation (communication line) | A, B, C, D, error |
Measuring connections |
L1, L2, L3, N, PE |
max. 250 / 430 V AC, 10 A | |
laboratory plug | |
Schuko connection | max. 250 V AC, 10 A |
Fuse from the Schuko connection | fuse F 10 A / 250 V, 5 x 20 mm / 0.19 x 0.78'' |
CP signal output | ± 12 V PWM |
Input voltage |
1 phase: 250 V AC / 3 phase 430 V AC, |
50 / 60 Hz, max. 10 A | |
Charging cable connector Type 1 |
AC charging mode 3, compatible with IEC62196-1 |
Type 1 or SAE J1772 with vehicle connection | |
(Type 1, 5 pin, 1-phase) | |
Charging cable connector Type 2 |
AC charging mode 3, compatible with IEC62196-2 |
Type 1 or SAE J1772 with vehicle connection | |
(Type 2, 7 pin, 3-phase) | |
Measurement category | CAT II 300 V |
Protection class | IP54 |
Pollution degree | 2 |
Operating conditions | 0 ... 40 °C / 32 ... 104 °F, 10 ... 85% RH, non-condensing |
Storage conditions | -10 ... 50 °C / 14 ... 122 °F, 10 ... 60% RH, non-condensing |
Maximum working height | max. 2000 m / 6561 ft |
Dimensions (handheld only) | 277 x 109 x 63 mm / 10.9 x 4.3 x 2.4'' |
Weight | ca. 1 kg / 2.2 lb |
available in | ||